1. Conditioning Samples should be fully conditioned, preferably to the same temperature and humidity as the standard they are being compared to. ASTM standard conditions are 70 F +/-2 and relative humidity of 65% +/-2%. 2. Spectrophotometer settings: The spectrophotometer’s area view or aperture should be as large as the sample will allow and [...]